Skip to content
0% OFF
Hover to Zoom
Velfix Secure- Foley Fixation Dressing- Similar To Fixocath And Statlock

Velfix Secure – Foley Fixation Dressing – Similar To Fixocath And Statlock

In Stock
Estimated Delivery within 2 Days
COD Available
Price range: ₹149.00 through ₹2,499.00
  • Hypoallergenic adhesive minimizes the risk of skin irritation or allergies, prioritizing patient safety.
  • The breathable design of our product ensures it's gentle on the skin, enhancing patient comfort throughout use.
  • Enhanced patient care is achieved as our dressing reduces the need for frequent catheter repositioning, allowing healthcare providers to concentrate on delivering quality care.
  • Time and Cost Savings are realized through the easy application and removal process of our dressing, saving valuable time for healthcare professionals.
  • Healthcare providers can trust in the stability and integrity of urinary catheters when using our product, ensuring optimal patient outcomes.

 

Buy Velfix Secure – Foley Fixation Dressing – Similar To Fixocath And Statlock

C.R. Bard FOL0102 – StatLock Foley Stabilization Device, Tricot Anchor Pad, for Silicone Catheter, Adult,

C.R. Bard FOL0102 StatLock Foley Stabilization Device

StatLock Stabilization Devices are a more effective alternative to tape in helping improve clinical outcomes, quality of care and economic efficiency. The StatLock Foley stabilization device accommodates latex 8-22 Fr. and silicone 8-26 Fr. catheters for the ultimate in versatility. Available in adult and pediatric sizes.

C.R. Bard FOL0102 StatLock Foley Stabilization DeviceFeatures and Benefits

  • Reduce Foley catheter movement
  • Minimize accidental catheter dislodgements
  • Maximize patient comfort by:
    • Eliminating circumferential compression
    • Alleviating traction of urethral catheters
  • The StatLock Foley Stabilization Device sets new, worldwide standard for Foley catheter stabilization.
  • Featuring a patented swivel retainer for enhanced patient comfort and convenience.
  • Available in adult and pediatric sizes for most latex and silicone catheters.
  • Releasable, lock-tight securement.

StatLock Device Retainer Design

  • Lock-tight design stabilizes catheter to prevent pistoning and accidental dislodgement.
  • Swivel design allows catheter movement with the patient without exerting a pull force on the catheter.
  • Releasable design allows for easy cleaning of patient.
  • Accommodates both 2-way and 3-way latex 822 Fr. and silicone 626 Fr. catheters for the ultimate in versatility.

StatLock Device Anchor Pad Design

  • Available in breathable latex-free tricot fabric for added patient comfort.
  • Available in both pediatric and adult sizes, giving you the versatility needed for effective Foley catheter stabilization.
  • Designed to be easier to use than tape and circumferential leg straps.
  • Unique alcohol-soluble adhesive is gentle on the skin.

Warnings and Precautions of C.R. Bard FOL0102 StatLock Foley Stabilization Device

  • Do not use the StatLock device where loss of adherence could occur, such as with a confused patient, diaphoretic or non-adherent skin, or when the access device is not monitored daily.
  • Observe universal blood and body fluid precautions and infection control procedures, during application and removal of the StatLock device.
  • Minimize catheter manipulation during application and removal of the

C.R. Bard FOL0102 StatLock Foley Stabilization Device Application Technique

Prep

  • 1.Place Foley catheter into retainer. Directional arrow should point towards catheter tip, and balloon inflation arm should be next to the clamp hinge.
  • 2. Close lid, being careful to avoid pinching the catheter.
  • 3. Identify securement site by laying the device retainer on the front of the thigh, leaving 1 inch of catheter slack between insertion site and the StatLock device retainer.
  • 4. After placing the StatLock Stabilization device off to the side, cleanse and degrease the securement site with alcohol per hospital policy. Let skin dry.
  • 5. Apply skin protectant, in direction of hair growth, to area larger than securement site. Allow to dry completely (10-15 seconds).
  • 6. Using permanent marker, write initials and date of application on the StatLock device anchor pad.