Helmier Prosyte Two Lumen Extention With Needle - Surgical Dekho
Welcome to Surgicaldekho. We Provides Online Surgical Supply Store

Helmier Prosyte Two Lumen Extention With Needle

Original price was: ₹708.00.Current price is: ₹160.00.

Estimated Order delivered within 2 days
  • Demonstrates minimum blood reflux from moving into the catheter lumen upon connection or disconnection” which reduces incidences of catheter occlusion as compared to negative & positive displacement devices 1
  • The Anti reflux action in connector helps maintain line patency ,prevents blood from entering into catheter thus there is less need to remember clamping sequence 2
  • Transparent connector body to assess visible fluid pathway which ensures that flushing leaves the housing free of visible blood and prevent blood borne contamination risk 3
  • Simple Design delivering Straight fluid path reduces microbial ingress
  • Split Septum Technology with no moving parts reduces the internal surface for biofilm formation 4a
  • Less residual volume ensures adequate flushing 4b
  • No risk of haemolysis during blood draws 4c

In Stock

-
+
Add to Wishlist
Add to Wishlist

Description

Helmier Prosyte Two Lumen Extention With Needle

  1. Hadaway, Lynn & Richardson, Deb. (2010). Needleless Connectors. Journal of infusion nursing : the official publication of the Infusion Nurses Society. 33. 22-31. 10.1097/NAN.0b013e3181c65cc9.)_
  2. Curran E. (2016). Needleless connectors: the vascular access catheter’s microbial gatekeeper. Journal of infection prevention, 17(5), 234–240. https://doi.org/10.1177/1757177416657164), CDC 2011 :Potential explanations for outbreaks include (…) inadequate flushing of the device due to poor visualization of the fluid flow pathway in opaque devices, Jarvis W. 2010 :The ability to visualize the internal surfaces of the needleless connector helps the clinician determine if flushing of the needleless connector is complete (…) A transparent needleless connector is preferable to one that is opaque
  3. A split-septum needleless access system has 64%–70% lower CRBSI rates than mechanical valves Rupp ME, Sholtz LA, Jourdan DR, et al. Outbreak of bloodstream infection temporally associated with the use of an intravascular needleless valve. CID. 2007;44:1408-1414.
  4. Salgado CD, Chinnes L, Paczesny TH, Cantey JR. Increased rate of catheter-related bloodstream infection associated with use of a needleless mechanical valve device at a long-term acute care hospital. Infect Control Hosp Epidemiol. 2007;28:684-688.
  5. Simple fluid path design reduces places for microbes to grow;(PDF) Health Care-Associated Bloodstream Infections Associated with Negative- or Positive-Pressure or Displacement Mechanical Valve Needleless Connectors (researchgate.net)

 

Reviews

There are no reviews yet.

Be the first to review “Helmier Prosyte Two Lumen Extention With Needle”

Your email address will not be published. Required fields are marked *

0